BuyAGenerator.com · Backup power plan builder

Planning · Free tool

Backup power plan builder

A backup power plan starts with three honest questions: what has to stay on, how big a project you're ready to take on, and which goal matters most. This free planner turns your answers into a short, ordered plan. Start with a load list that shows planning ranges for running and starting watts, then pick a budget tier and a goal. Each step links to the guide on this site that explains it, from sizing and transfer switches to outdoor placement and installer quotes. There's no signup and no email. Your choices stay in your browser, and you can print the plan, your load worksheet and an outage checklist. It's a starting point for your own nameplates and local quotes, not a product pick.

Last updated:

How it works

  1. List what you need to run

    Tick the loads that matter, add your own, and see a planning range for running and starting watts.

  2. Choose your budget

    Pick one of three published cost tiers, from cords to a standby generator. They describe the size of the project, not a dollar figure.

  3. Choose your goal

    Pick what has to stay on: the essentials, water from a well, heat, or most of the house.

  4. Get your plan

    See the steps in order, each linked to the guide that explains it. Print it or bookmark the page to keep it.

What matters for each goal

Planning ranges from our guides. Your nameplates replace them. Cost is shown as the published scope tier, not dollars.

Numbers, transfer path and cost tier by goal
GoalNumbers that matterTransfer pathPublished cost tierRead next
Keep the essentials onFridge 100–250 W running, 600–1,200 W starting (planning range). The sizing guide's layer 1 example peaks at 1,010 W. (Critical load worksheet, Generator sizing guide)Cords for plug-in loads, or a power station where exhaust isn't allowed“Cords tier: outdoor-rated cords, fuel containers, CO alarms, and your time. No panel work.” SourceRead: Critical load worksheet
Keep water running (well pump)Well pump 750–2,500 W running, 2,000–6,000+ W starting. The sizing guide's well-and-furnace example peaks at 5,850 W. (Critical load worksheet, Generator sizing guide)A permitted inlet with interlock or a manual transfer switch, or standby with an ATS“Inlet + interlock or manual transfer tier: hardware plus electrician labor, usually a permit and inspection. A small electrical project, not a warehouse impulse buy.” SourceRead: Critical load worksheet
Whole-house standbykW class and ATS amp rating sized to your worksheet. Still not every appliance at once unless sized and managed. (Standby generator installed cost)Automatic transfer switch, often with load management“Standby + ATS tier: equipment, pad, fuel work, ATS, permit, inspection, commissioning. A small construction project with longer lead time.” SourceRead: Standby generator installed cost
Planning for a multi-day outage season (for example, in North Carolina)Runtime in days is a fuel plan. With metered natural gas or a sized propane tank, standby becomes realistic for multi-day runtime. Cold changes how each fuel behaves. (Home generator types, Winter generator fuel and cold-weather operation)Any of the paths above, chosen from your worksheetAny of the three tiers above; your worksheet picks oneRead: Home generator types

Build your plan

The interactive planner needs JavaScript. Everything it builds is still on this page: the load list below shows planning ranges, the example plans walk through three common setups, and every plan at a glance lists all twelve budget and goal combinations.

  1. Loads
  2. Budget
  3. Goal
  4. Plan

What do you want to keep running?

Tick what matters. Figures are planning ranges from our critical load worksheet. Your nameplate wins.

Load list with planning ranges for running and starting watts
Keep runningLoadRunning (planning)Starting / surge (planning)Priority layerUsually
100–250 W600–1,200 W1plug-in
100–300 W600–1,400 W1plug-in
10–150 Wnone (no motor)1plug-in
10–40 Wnone (no motor)1plug-in
45–100 Wnone (no motor)1plug-in
5–20 Wnone (no motor)1plug-in
50–200 Wnone (no motor)3plug-in
800–1,500 W1,500–3,000 W2plug-in
750–2,500 W2,000–6,000+ W2hardwired
400–1,000 W800–2,000 W2hardwired
500–1,500 W1,000–3,000 W2plug-in
800–1,500 Wnone (no motor)3plug-in
800–1,500 Wnone (no motor)3plug-in
1,000–1,500 Wnone (no motor)3plug-in
300–600 W600–1,200 W3hardwired
2,000–5,000+ Wnone (no motor)3hardwired
3,000–4,500 Wnone (no motor)3hardwired

Priority layers follow the worksheet: 1 is communications and cold food, 2 is one zone of heat or water, 3 is everything else. If someone depends on a medical device, put it first and check the maker's power guidance.

Not in the list?

Central air, a heat pump, a dryer, a washer, a dishwasher, a dehumidifier, a hardwired sump, a shop compressor or a medical device have no published planning range here, so add them as your own load from the nameplate.

Add your own load

(your own watts, or a medical device)

Read watts from the plate, or volts × amps. Leave starting blank if it has no motor. If someone depends on a medical device, put it first and check the maker's power guidance.

    Tick a load to see a planning range.

    Choose your budget

    Three published cost tiers. They describe the size of the project, not a dollar figure.

    From the transfer switch guide

    From the transfer switch guide

    From the transfer switch guide

    Choose your goal

    Example plans

    Three common setups, built the same way the planner builds yours. Every step links to the guide it comes from.

    Example plan

    Essentials on the smallest spend

    Budget: Smallest spend: cords and a portable or a power station · Goal: Keep the essentials on

    The 9 steps
    1. List your must-run loads on the critical load worksheet: fridge, a lamp or two, router or modem, phone chargers. Mark each one plug-in or hardwired.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Add up running watts from the nameplates and allow for the fridge compressor's start surge.

      Read the generator sizing tool guide
    4. Plan to feed plug-in loads with outdoor-rated cords of the right gauge from a portable running outdoors. No panel work.

      Published cost tier“Cords tier: outdoor-rated cords, fuel containers, CO alarms, and your time. No panel work.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    5. If outdoor exhaust is not allowed where you live, compare a power station instead of a gas portable.

      Published cost tier“Power station: appliance-like purchase; no transfer switch; you are done when the carton is open.” Source: Battery backup vs generator

      Read: Portable power stations vs gas generators
    6. Start with what the budget allows: cover the must-run list now, and note which loads would need a transfer path later so the next step is already planned.

      Read: Transfer switch vs interlock
    7. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    8. Set up the before-the-outage checklist: fuel, oil, cords and alarms found and ready.

      Read: Home power outage checklist
    9. Put a start test and oil check on your calendar so the machine runs when you need it.

      Read: Generator maintenance calendar
    Example plan

    Keeping the well pump running

    Budget: Middle: a permitted inlet with interlock or a manual transfer switch · Goal: Keep water running (well pump)

    The 10 steps
    1. Build the worksheet the way worked example B does: well, fridge, lights, and the furnace blower if you have one. Mark the well hardwired.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Read the well pump's plate and size for its starting surge, not just running watts.

      Read the generator sizing tool guide
    4. Plan a permitted inlet with interlock or a manual transfer switch so the hardwired well can be fed legally.

      Published cost tier“Inlet + interlock or manual transfer tier: hardware plus electrician labor, usually a permit and inspection. A small electrical project, not a warehouse impulse buy.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    5. Set an operating rule: don't start the well and another large motor in the same minute.

      Read: Critical load worksheet
    6. Ask each electrician for the same quote lines, including the inlet amp rating and which circuits are covered.

      Read: Generator installer quote checklist
    7. Start with what the budget allows and leave room to grow: an interlock lets you change which breakers you feed as priorities shift, within the generator's rating.

      Read: Transfer switch vs interlock
    8. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    9. Run the before-the-outage checklist, including the posted switch-over sequence.

      Read: Home power outage checklist
    10. Put a start test and oil check on your calendar.

      Read: Generator maintenance calendar
    Example plan

    Whole-house standby

    Budget: Largest: a standby generator with an automatic transfer switch · Goal: Run most of the house

    The 10 steps
    1. Sort every load into layers on the worksheet. Layer 3 is a standby-and-load-management conversation.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Size from nameplates and surge, not square footage.

      Read the generator sizing tool guide
    4. Ask for bids in the larger tier. Even then, not every appliance runs at once unless it is sized and managed.

      Published cost tier“Larger whole-home-ish standby · More circuits or a whole-panel / managed whole-home conversation · Still not every appliance at once unless sized and managed; bigger site and electrical scope” Source: Standby generator installed cost

      Read: Standby generator installed cost
    5. Go through the cost drivers that move the bill: equipment, pad, ATS, fuel work, permits and electrical labor.

      Published cost tier“Standby + ATS tier: equipment, pad, fuel work, ATS, permit, inspection, commissioning. A small construction project with longer lead time.” Source: Transfer switch vs interlock

      Read: Standby generator installed cost
    6. Give every installer the same bid lines and compare two complete quotes line by line.

      Read: Generator installer quote checklist
    7. If you also have solar or want a battery, compare a whole-home setup with a critical-loads panel.

      Read: Grid-tie solar with battery backup
    8. Start with what the budget allows and leave room to grow: an essential-circuit standby sized to your worksheet is a sound start, and a larger tier with load management can be chosen later.

      Read: Standby generator installed cost
    9. Confirm the standby pad keeps exhaust away from doors, windows and vents, and put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    10. Plan the exercise runs and yearly service.

      Read: Generator maintenance calendar

    Every plan at a glance

    Show all 12 plans (three budget bands, four goals)
    Smallest spend: cords and a portable or a power station · Keep the essentials on
    1. List your must-run loads on the critical load worksheet: fridge, a lamp or two, router or modem, phone chargers. Mark each one plug-in or hardwired.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Add up running watts from the nameplates and allow for the fridge compressor's start surge.

      Read the generator sizing tool guide
    4. Plan to feed plug-in loads with outdoor-rated cords of the right gauge from a portable running outdoors. No panel work.

      Published cost tier“Cords tier: outdoor-rated cords, fuel containers, CO alarms, and your time. No panel work.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    5. If outdoor exhaust is not allowed where you live, compare a power station instead of a gas portable.

      Published cost tier“Power station: appliance-like purchase; no transfer switch; you are done when the carton is open.” Source: Battery backup vs generator

      Read: Portable power stations vs gas generators
    6. Start with what the budget allows: cover the must-run list now, and note which loads would need a transfer path later so the next step is already planned.

      Read: Transfer switch vs interlock
    7. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    8. Set up the before-the-outage checklist: fuel, oil, cords and alarms found and ready.

      Read: Home power outage checklist
    9. Put a start test and oil check on your calendar so the machine runs when you need it.

      Read: Generator maintenance calendar
    Smallest spend: cords and a portable or a power station · Keep water running (well pump)

    This goal needs more than this budget band covers. The plan below says where the limit is and what the next band adds.

    1. Know the limit first: cords only feed plug-in loads. A hardwired well pump can't run on extension cords.

      Published cost tier“Cords tier: outdoor-rated cords, fuel containers, CO alarms, and your time. No panel work.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Read the well pump's volts and amps from the motor or controller plate and mark it hardwired on the worksheet.

      Read: Critical load worksheet
    4. Estimate the pump's starting surge with the sizing tool, so you know the generator size a transfer path would need.

      Read the generator sizing tool guide
    5. To keep the well on, the next step up is a permitted inlet with interlock or a manual transfer switch. See the middle-budget plan for water.

      Published cost tier“Inlet + interlock or manual transfer tier: hardware plus electrician labor, usually a permit and inspection. A small electrical project, not a warehouse impulse buy.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    6. Until a legal transfer path is in, the well waits for the utility. Plan stored water and keep the rest of the outage routine.

      Read: Home power outage checklist
    7. Start with what the budget allows: cover the must-run list now, and note which loads would need a transfer path later so the next step is already planned.

      Read: Transfer switch vs interlock
    8. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    Smallest spend: cords and a portable or a power station · Keep heat running

    This goal needs more than this budget band covers. The plan below says where the limit is and what the next band adds.

    1. Know the limit first: cords only feed plug-in loads. A hardwired furnace blower can't run on extension cords.

      Published cost tier“Cords tier: outdoor-rated cords, fuel containers, CO alarms, and your time. No panel work.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Mark the furnace blower and controls hardwired on the worksheet, and read the blower's nameplate.

      Read: Critical load worksheet
    4. Estimate the blower's running and starting watts with the sizing tool.

      Read the generator sizing tool guide
    5. To keep heat on, the next step up is a permitted inlet with interlock or a manual transfer switch. See the middle-budget plan for heat.

      Published cost tier“Inlet + interlock or manual transfer tier: hardware plus electrician labor, usually a permit and inspection. A small electrical project, not a warehouse impulse buy.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    6. Until then, plan the cold-weather routine for the loads cords can carry: fuel that suits the cold and a dry outdoor spot.

      Read: Winter generator fuel and cold-weather operation
    7. Start with what the budget allows: cover the must-run list now, and note which loads would need a transfer path later so the next step is already planned.

      Read: Transfer switch vs interlock
    8. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    Smallest spend: cords and a portable or a power station · Run most of the house

    This goal needs more than this budget band covers. The plan below says where the limit is and what the next band adds.

    1. Know the limit first: most of the house is layer 3 on the worksheet, which is a standby-and-load-management conversation, not a cords plan.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Trim the list to layer 1: fridge, lights, communications. Mark everything else leave off.

      Read: Critical load worksheet
    4. Size the layer 1 list from nameplates.

      Read the generator sizing tool guide
    5. Feed that list with outdoor-rated cords from a portable running outdoors.

      Published cost tier“Cords tier: outdoor-rated cords, fuel containers, CO alarms, and your time. No panel work.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    6. If you still want most of the house on, compare the standby path and see the largest-budget plan.

      Published cost tier“Standby + ATS tier: equipment, pad, fuel work, ATS, permit, inspection, commissioning. A small construction project with longer lead time.” Source: Transfer switch vs interlock

      Read: Portable vs standby generators
    7. Start with what the budget allows: cover the must-run list now, and note which loads would need a transfer path later so the next step is already planned.

      Read: Transfer switch vs interlock
    8. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    9. Set up the before-the-outage checklist.

      Read: Home power outage checklist
    Middle: a permitted inlet with interlock or a manual transfer switch · Keep the essentials on
    1. List your must-run loads on the critical load worksheet and mark which breakers they sit on.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Size the list from nameplates: running watts plus the largest start surge.

      Read the generator sizing tool guide
    4. Choose between an interlock on your main panel and a manual transfer switch with a fixed circuit list. Both need a licensed electrician and usually a permit.

      Published cost tier“Inlet + interlock or manual transfer tier: hardware plus electrician labor, usually a permit and inspection. A small electrical project, not a warehouse impulse buy.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    5. Tell the electrician whether your portable's neutral is bonded or floating, and let them match local code.

      Read: Transfer switch vs interlock
    6. Ask each electrician for the same quote lines so you can compare them fairly.

      Read: Generator installer quote checklist
    7. Start with what the budget allows and leave room to grow: an interlock lets you change which breakers you feed as priorities shift, within the generator's rating.

      Read: Transfer switch vs interlock
    8. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    9. Post the switch-over sequence by the panel and run the before-the-outage checklist.

      Read: Home power outage checklist
    10. Put a start test and oil check on your calendar.

      Read: Generator maintenance calendar
    Middle: a permitted inlet with interlock or a manual transfer switch · Keep water running (well pump)
    1. Build the worksheet the way worked example B does: well, fridge, lights, and the furnace blower if you have one. Mark the well hardwired.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Read the well pump's plate and size for its starting surge, not just running watts.

      Read the generator sizing tool guide
    4. Plan a permitted inlet with interlock or a manual transfer switch so the hardwired well can be fed legally.

      Published cost tier“Inlet + interlock or manual transfer tier: hardware plus electrician labor, usually a permit and inspection. A small electrical project, not a warehouse impulse buy.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    5. Set an operating rule: don't start the well and another large motor in the same minute.

      Read: Critical load worksheet
    6. Ask each electrician for the same quote lines, including the inlet amp rating and which circuits are covered.

      Read: Generator installer quote checklist
    7. Start with what the budget allows and leave room to grow: an interlock lets you change which breakers you feed as priorities shift, within the generator's rating.

      Read: Transfer switch vs interlock
    8. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    9. Run the before-the-outage checklist, including the posted switch-over sequence.

      Read: Home power outage checklist
    10. Put a start test and oil check on your calendar.

      Read: Generator maintenance calendar
    Middle: a permitted inlet with interlock or a manual transfer switch · Keep heat running
    1. List the furnace blower and controls plus your essentials on the worksheet. Mark the blower hardwired.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Size the list from nameplates, including the blower's start surge.

      Read the generator sizing tool guide
    4. Plan a permitted inlet with interlock or a manual transfer switch so the furnace circuit can be fed legally.

      Published cost tier“Inlet + interlock or manual transfer tier: hardware plus electrician labor, usually a permit and inspection. A small electrical project, not a warehouse impulse buy.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    5. Choose fuel that suits the cold and plan how you'll keep it ready.

      Read: Winter generator fuel and cold-weather operation
    6. Ask each electrician for the same quote lines so you can compare them fairly.

      Read: Generator installer quote checklist
    7. Start with what the budget allows and leave room to grow: an interlock lets you change which breakers you feed as priorities shift, within the generator's rating.

      Read: Transfer switch vs interlock
    8. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    9. Run the before-the-outage checklist.

      Read: Home power outage checklist
    10. Put a start test and oil check on your calendar.

      Read: Generator maintenance calendar
    Middle: a permitted inlet with interlock or a manual transfer switch · Run most of the house

    This goal needs more than this budget band covers. The plan below says where the limit is and what the next band adds.

    1. Know the limit first: an interlock lets you pick breakers within the generator's rating, but turning on every breaker still overloads a mid-size portable.

      Published cost tier“Inlet + interlock or manual transfer tier: hardware plus electrician labor, usually a permit and inspection. A small electrical project, not a warehouse impulse buy.” Source: Transfer switch vs interlock

      Read: Transfer switch vs interlock
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Sort the worksheet into layers and keep layer 3 (range, dryer, central air) on leave off.

      Read: Critical load worksheet
    4. Size the layers 1 and 2 list from nameplates.

      Read the generator sizing tool guide
    5. If you need most of the house on without someone switching it over, compare the standby path and see the largest-budget plan.

      Published cost tier“Standby + ATS tier: equipment, pad, fuel work, ATS, permit, inspection, commissioning. A small construction project with longer lead time.” Source: Transfer switch vs interlock

      Read: Portable vs standby generators
    6. Ask each electrician for the same quote lines so you can compare them fairly.

      Read: Generator installer quote checklist
    7. Start with what the budget allows and leave room to grow: an interlock lets you change which breakers you feed as priorities shift, within the generator's rating.

      Read: Transfer switch vs interlock
    8. Pick the outdoor spot before the first run: away from doors, windows and vents, never in a garage or basement. Put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    9. Run the before-the-outage checklist.

      Read: Home power outage checklist
    Largest: a standby generator with an automatic transfer switch · Keep the essentials on
    1. List your must-run loads on the critical load worksheet before you ask for any standby bid.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Size the list from nameplates and surge, not square footage.

      Read the generator sizing tool guide
    4. Check that standby fits: who is home, how long outages last, and which loads are hardwired.

      Read: Portable vs standby generators
    5. Ask for bids in the essential-circuit tier, sized to your worksheet.

      Published cost tier“Essential-circuit standby · Automatic backup for a managed set of breakers or a critical subpanel” Source: Standby generator installed cost

      Read: Standby generator installed cost
    6. Give every installer the same bid lines: equipment, pad, ATS, fuel work, permits, electrical labor, commissioning.

      Published cost tier“Standby + ATS tier: equipment, pad, fuel work, ATS, permit, inspection, commissioning. A small construction project with longer lead time.” Source: Transfer switch vs interlock

      Read: Generator installer quote checklist
    7. Start with what the budget allows and leave room to grow: an essential-circuit standby sized to your worksheet is a sound start, and a larger tier with load management can be chosen later.

      Read: Standby generator installed cost
    8. Confirm the standby pad keeps exhaust away from doors, windows and vents, and put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    9. Plan the exercise runs and yearly service.

      Read: Generator maintenance calendar
    Largest: a standby generator with an automatic transfer switch · Keep water running (well pump)
    1. Build the worksheet the way worked example B does and mark the well hardwired.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Size for the well pump's starting surge plus the essentials.

      Read the generator sizing tool guide
    4. Read the larger-home-with-a-well scenario: the well and sump go on the transfer plan, with load management so motors don't start together.

      Published cost tier“Standby + ATS tier: equipment, pad, fuel work, ATS, permit, inspection, commissioning. A small construction project with longer lead time.” Source: Transfer switch vs interlock

      Read: Standby generator installed cost
    5. Ask for bids in a named tier and give every installer the same bid lines, including the well circuit on the ATS.

      Read: Generator installer quote checklist
    6. Compare two complete quotes line by line before you compare totals.

      Read: Generator installer quote checklist
    7. Start with what the budget allows and leave room to grow: an essential-circuit standby sized to your worksheet is a sound start, and a larger tier with load management can be chosen later.

      Read: Standby generator installed cost
    8. Confirm the standby pad keeps exhaust away from doors, windows and vents, and put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    9. Plan the exercise runs and yearly service.

      Read: Generator maintenance calendar
    Largest: a standby generator with an automatic transfer switch · Keep heat running
    1. List the furnace or air handler plus your essentials on the worksheet.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Size the list from nameplates and surge.

      Read the generator sizing tool guide
    4. Ask for bids in the essential-circuit tier, with the furnace circuit on the ATS.

      Published cost tier“Essential-circuit standby · Automatic backup for a managed set of breakers or a critical subpanel” Source: Standby generator installed cost

      Read: Standby generator installed cost
    5. Check how your fuel choice behaves in the cold for a standby set.

      Read: Winter generator fuel and cold-weather operation
    6. Give every installer the same bid lines.

      Published cost tier“Standby + ATS tier: equipment, pad, fuel work, ATS, permit, inspection, commissioning. A small construction project with longer lead time.” Source: Transfer switch vs interlock

      Read: Generator installer quote checklist
    7. Start with what the budget allows and leave room to grow: an essential-circuit standby sized to your worksheet is a sound start, and a larger tier with load management can be chosen later.

      Read: Standby generator installed cost
    8. Confirm the standby pad keeps exhaust away from doors, windows and vents, and put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    9. Plan the exercise runs and yearly service.

      Read: Generator maintenance calendar
    Largest: a standby generator with an automatic transfer switch · Run most of the house
    1. Sort every load into layers on the worksheet. Layer 3 is a standby-and-load-management conversation.

      Read: Critical load worksheet
    2. Rank your loads for an outage: must-run first (communications and cold food), then one zone of heat or water. Leave everything else off until it fits.

      Read: Critical load worksheet
    3. Size from nameplates and surge, not square footage.

      Read the generator sizing tool guide
    4. Ask for bids in the larger tier. Even then, not every appliance runs at once unless it is sized and managed.

      Published cost tier“Larger whole-home-ish standby · More circuits or a whole-panel / managed whole-home conversation · Still not every appliance at once unless sized and managed; bigger site and electrical scope” Source: Standby generator installed cost

      Read: Standby generator installed cost
    5. Go through the cost drivers that move the bill: equipment, pad, ATS, fuel work, permits and electrical labor.

      Published cost tier“Standby + ATS tier: equipment, pad, fuel work, ATS, permit, inspection, commissioning. A small construction project with longer lead time.” Source: Transfer switch vs interlock

      Read: Standby generator installed cost
    6. Give every installer the same bid lines and compare two complete quotes line by line.

      Read: Generator installer quote checklist
    7. If you also have solar or want a battery, compare a whole-home setup with a critical-loads panel.

      Read: Grid-tie solar with battery backup
    8. Start with what the budget allows and leave room to grow: an essential-circuit standby sized to your worksheet is a sound start, and a larger tier with load management can be chosen later.

      Read: Standby generator installed cost
    9. Confirm the standby pad keeps exhaust away from doors, windows and vents, and put a working CO alarm on every level.

      Read: Generator placement and carbon monoxide safety
    10. Plan the exercise runs and yearly service.

      Read: Generator maintenance calendar

    How we build your plan

    Every plan comes from guides already published on BuyAGenerator.com. We don't add brands, models or prices, and no step is paid for.

    Where the numbers come from

    Full math: watts, surge, fridge duty cycle and battery runtime
    • Watts. Running and starting figures in the load list are the planning ranges in our critical load worksheet. They are not lab measurements or model claims. Your nameplate wins: watts = volts × amps.
    • Planning peak (surge). We add the running watts of everything that may be on together, then add only the largest extra start (starting minus running), as our sizing guide does. Two motors starting in the same minute raise the peak, so stagger them.
    • Fridge average (duty cycle). A fridge cycles, so we don't use a flat figure. We take the yearly energy on the yellow EnergyGuide label and divide by the hours in a year: 560 kWh × 1,000 ÷ 8,760 h = 63.9 W, about 64 W. ENERGY STAR lists about 360 kWh a year for a certified top-freezer model, about 560 kWh for a bottom-freezer model and about 630 kWh for a side-by-side (ENERGY STAR quick reference guide). Against a 180 W running plate from our sizing guide example, 63.9 W means the compressor runs about 36% of the time, roughly 21 minutes an hour. Use your own label: kWh a year ÷ 8.76 = average watts. An outage day with the doors kept shut may run less; a warm kitchen or frequent opening runs more.
    • Battery runtime. Usable watt-hours × 0.90 ÷ average watts ≈ hours. The 0.90 is the about-10% inverter and wiring loss our battery vs generator guide, power station guide and hybrid solar guide use. Capacity means usable watt-hours after the pack's depth-of-discharge limit, which is often less than the number on the box. The example uses 2,000 Wh and 5,000 Wh, sizes our guides already show: 2,000 Wh × 0.90 ÷ 123.9 W ≈ 14.5 hours; 5,000 Wh × 0.90 ÷ 123.9 W ≈ 36.3 hours.
    • Cost. We publish cost as scope tiers, not dollars. Your local quotes fill in the dollars.

    Runtime example: the same three loads on two battery sizes

    Example A refrigerator (about 64 W average), a router and modem (20 W) and LED lights in two rooms (40 W): about 124 W together. Battery sizes are generic usable capacities, not models.

    Runtime of the example loads on two usable battery capacities
    Usable capacityAfter about 10% lossAverage drawRuntime
    2,000 Wh usable (battery vs generator guide)1,800 Whabout 124 Wabout 14.5 hours
    5,000 Wh usable (battery vs generator guide)4,500 Whabout 124 Wabout 36.3 hours

    Fridge average: 560 kWh a year ÷ 8,760 hours ≈ 64 W, from the ENERGY STAR figure for a certified bottom-freezer refrigerator, not a flat guess. Add a 1,500 W space heater and the same 2,000 Wh lasts about 1.2 hours (battery vs generator guide). Generator runtime is a fuel question; see the winter fuel guide. Where the numbers come from

    Written and reviewed by Gregg Jahn. See our editorial policy. This is educational planning, not electrical or legal advice; a licensed electrician decides what is safe for your panel.

    Plan link: https://www.buyagenerator.com/backup-power-plan-builder.html

    Educational planning only. Size from your own nameplates and get local quotes. By Gregg Jahn.